home *** CD-ROM | disk | FTP | other *** search
- Path: user1.mnsinc.com!mintz
- From: mintz@mnsinc.com (Larry Mintz)
- Newsgroups: comp.dcom.modems
- Subject: Re: USR Sportster 33.6: Locking DTE for incoming calls
- Date: 5 Apr 1996 14:00:34 GMT
- Organization: Monumental Network Systems
- Message-ID: <4k3922$ec6@news1.mnsinc.com>
- References: <4k16us$108@icaros.softlab.ece.ntua.gr>
- NNTP-Posting-Host: user1.mnsinc.com
- cc: alex@pouliadis.gr
- X-Newsreader: TIN [version 1.2 PL2]
-
- Alexander Couloumbis (acoul@softlab.ece.ntua.gr) wrote:
- : The manual says that you have to set the Sportster
- : with at&b1 if you want to have the DTE locked at
- : the speed that you entered the last at command.
-
- : What is the case though when you have the USR turned
- : ON waiting for incoming calls? On the multitechs
- : you can sellect a forced DTE speed by supplying
- : a at$MBbaudrate
-
- When you issue the AT&W command with the fixed baud rate option enabled,
- whatever baud rate you issued the &W (or &W1) command at is the rate at
- which the modem's DTE will remain (and will be reset to if you do an ATZ
- or ATZ1.)
-
- Larry
-